Careers Business Ownership Definition and Guidelines for Rebar Lap Splices Share PINTEREST Email Print Business Ownership Industries Construction Retail Small Business Restauranting Real Estate Nonprofit Organizations Landlords Import/Export Business Freelancing & Consulting Franchises Food & Beverage Event Planning eBay E-commerce Operations & Success Becoming an Owner By Juan Rodriguez Juan Rodriguez LinkedIn University of Puerto Rico DeVry University Juan Rodriguez is a former writer with The Balance who covered large-scale construction. He is an engineer with experience managing and overseeing large civil works construction. Learn about our Editorial Process Updated on 04/13/20 Reinforcing bars (rebars) come in lengths of up to 60 feet. In theory, this would seem to obviate the need for splicing the material for all but the largest commercial projects. In practice, however, most building projects involve extensive rebar splicing. This may be due to any number of reasons, such as shipping constraints on length and efficient use of materials. A lap splice is the most common method of creating a single structural entity from two rebar segments. The lap splice, as the name suggests, is created by overlapping two lengths of rebar, then wiring them together. From a structural point of view, the most critical aspect of a lap splice is the overlap length. Note, however, that overlap requirements vary with both rebar size and the specific structural application. Rebar Lap Splice Model Codes In almost every construction situation, overlap lengths are subject to local building codes. Although it's imperative to check your local code for detailed compliance requirements, most codes are based on the International Building Code (IBC). IBC code requirements are almost identical to the American Concrete Institute (ACI) codes. ACI code section 318-14, which governs rebar splicing, has been incorporated without meaningful modification into the corresponding concrete section of the 2015 and 2018 IBC. Therefore, either the IBC code sections governing concrete or ACI 318-14, current as of 2016, provide reliable information about lap splice code requirements. Local Code Is the Law Keep in mind that the governing code for your project is the local building code. Inspectors will not pass a project that is IBC code-compliant if it conflicts with the local version of the code. Furthermore, almost all U.S. jurisdictions now require a structural engineer's approval stamp on any structural aspect of the building plan. A structural engineer will take into account the standard requirements as well as exceptions for critical stress points, different splice length requirements when connecting rebar of different diameters, and requirements for staggering splices to prevent congestion at overlap points, which can result in inadequate concrete flow into the splice area. All splice locations must be specified in the structural plans before approval. Contact Splice Specifications The following are the IBC/ACI splice length requirements for the most common type of lap splice, the contact splice. Other types of splices that are code-compliant include mechanical splices and welded splices. Wiring Requirements for Lap Splicing Rebar Concrete Strength Steel Grade Rebar Type Splice Length 2,500 psi 60,000 #4 41 inches 2,500 psi 60,000 #5 51 inches 2,500 psi 60,000 #6 61 inches 2,500 psi 60,000 #7 89 inches 2,500 psi 60,000 #8 102 inches 3,000 psi 60,000 #4 37 inches 3,000 psi 60,000 #5 47 inches 3,000 psi 60,000 #6 56 inches 3,000 psi 60,000 #7 81 inches 3,000 psi 60,000 #8 93 inches The code requirements for the wiring material and fastening method are brief and note only that the wiring method employed should "secure" the rebar in place. The lack of specific requirements for the wiring material or specification of the wire wrapping method may seem surprising at first, but the wire's sole purpose is to hold the rebar temporarily in place. Once the pour is completed and the concrete has begun to harden (within a few hours of the pour), the wiring material has no further purpose. Standard splice lengths do not apply when the rebar needs to be drilled into the concrete. In this case, the structural engineer must determine the embedded depth of the rebar and the appropriate product to anchor the rebar to the existing concrete. By clicking “Accept All Cookies”, you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts. Cookies Settings Accept All Cookies